Aprilaire 8126 Ventilation Control System

Aprilaire 8126 Ventilation Control System

Aprilaire 8126 Ventilation Control System

Availability: Out of stock

Quick Overview

The Aprilaire 8126 24V Ventilation Control System continuously monitors the indoor relative humidity and the outdoor temperature.

Details

The Aprilaire Model 8126 Ventilation Control System continuously monitors indoor relative humidity, outdoor temperature and a useradjusted timer setting. Indoor relative humidity is monitored to help prevent high humidity conditions inside homes. The Aprilaire ventilation Controller will not open the damper to outside air if there is a chance of raising the humidity inside the house to high levels. The Aprilaire Ventilation Controller is designed to prevent indoor relative humidity levels from increasing beyond 60% due to ventilation. If the outdoor air temperature is below 0 degrees F or above 100 degrees F, the motorized, normally-closed damper to the outside wall will not open. Includes electric damper, 8120 controler, 8052 outdoor air sensor and transformer.

The Aprilaire 8126 24V Ventilation Control System is a great addition to your home heating and cooling system. The Aprilaire 8126 24V Ventilation Control System continuously monitors the indoor relative humidity and the outdoor temperature. The Aprilaire 8126 24V Ventilation Control System features user friendly settings that allow you to manage the quality of the air in your home year-round with very little effort. The Aprilaire 8126 24V Ventilation Control System includes the transformer, 8120 ventilation controller, and a six inch diameter power open, normally closed damper.

Complementing any central heating system, the Aprilaire Model 8126 Ventilation System:

  • Can be set not to ventilate if the outdoor temperature is above 100 degrees or below 0
  • Can be set to only ventilate if the furnace is running when the temperatures are under 20 degrees
  • Can be set not to run if the relative humidity in the house rises to 55% or higher
  • Has adjustable cycle times of one to for hours with run times that are adjustable from 0 - 60 minutes
  • Includes 6" normally closed power damper to insure that air only enters the house when you need it
  • Once the unit is set, the automatic controller will always bring in the right amount of fresh air for you

Additional Information

TypeNo
Model Number8126
BrandAprilaire

Technical Specs

Controller Specifications

  • Input (R,C): 18 to 30 VAC, 1 Amp Maximum
  • Damper Output: 18 to 30 VAC
  • Temperature Accuracy: + or - 2 °F
  • Relative Humidity Accuracy: + or - 5% RH
  • Cycle Time: 1, 2, 3, 4 (selectable) Hour(s)
  • Ventilation Time: 0 to 60 Minutes

Damper Specifications

  • Normally-closed, power open
  • Voltage: 24 VAC
  • Amps: 0.41
  • Length: 10-3/4"
  • Diameter: 6"
  • Max Static Pressure: 1.0 WC

Manuals

View and download product specifications below:
Aprilaire 8126 Owners Manual